Difference between revisions of "Intraoral Catheter"
(updated order information for adhesive) |
(updated small parts -> amazon link for washers; updated PE90 link) |
||
Line 13: | Line 13: | ||
Intraoral catheter: | Intraoral catheter: | ||
:PE90 .034" ID .050" OD x 6 inches in length | :PE90 .034" ID .050" OD x 6 inches in length | ||
− | :Intramedic | + | :BD Intramedic #427420, ordered from VWR #63018-704 for 10' at $50 |
Anchor washer for mouth: | Anchor washer for mouth: | ||
:PTFE Flat washer Ansi #0 .068 ID .188 OD .025 thick | :PTFE Flat washer Ansi #0 .068 ID .188 OD .025 thick | ||
− | :[https://www. | + | :[https://www.amazon.com/Washer-0-068-0-188-0-025-Thick/dp/B000FMYC7K Amazon] B000FMYC7K $5.61/package of 10 |
Line 27: | Line 27: | ||
Silastic sleeve: | Silastic sleeve: | ||
− | :.058" ID .077" OD | + | :.058" ID .077" OD silicone tubing, approx. 1 inch in length |
+ | : (not sure of current source) | ||
Latest revision as of 15:39, 17 December 2024
Method Description
Intraoral Catheterization and Infusions
Under isoflurane anesthesia, rats (n=16) were implanted with intraoral catheters made of PE-90 tubing that entered the mouth through the lateral check and were externalized on the dorsal surface between the scapulae, as described previously (Eckel and Ossenkopp, 1994). Intraoral catheters were flushed daily with water to maintain patency. For intraoral infusions, rats were weighed and placed in a glass aquarium subdivided into 4 individual compartments by Plexiglas sheets. Syringe pumps infused fluid into the mouth at a rate of 1 ml/min over 6 min. The rats were observed during the intraoral infusions; the time at which the rats first allowed the sucrose to passively drip from their mouths was recorded to the nearest second as the latency to drip. After the infusion, rats and any feces were weighed again as a measure of consumption, and rats were returned to their home cages.
To habituate rats to intraoral infusions, four days after surgery the rats were removed from their home cages and given intraoral infusions of deionized distilled water (6 ml over 6 min) on three consecutive days. After the third water infusion, rats were overnight food-deprived. Rats (n=8) received an infusion of 5% sucrose (6 ml/6 min) followed 30 minutes later by an injection of LiCl (0.15M, 12 ml/kg, i.p.). A separate group of rats received an intraoral infusion of 5% sucrose (6 ml/6 min) followed 30 min later by an injection of NaCl (0.15M, 12 ml/kg, i.p.). Food was returned one hour after the injections. On the final test day, rats recieved an intraoral infusion of 5% sucrose (6 ml / 6 min).
Materials
Intraoral catheter:
- PE90 .034" ID .050" OD x 6 inches in length
- BD Intramedic #427420, ordered from VWR #63018-704 for 10' at $50
Anchor washer for mouth:
- PTFE Flat washer Ansi #0 .068 ID .188 OD .025 thick
- Amazon B000FMYC7K $5.61/package of 10
Retaining Washer on back:
- instead of using a teflon washer as indicated, we make our own that have smaller ID and larger OD
- punch out disc of thin plastic using standard office hole punch; melt hole with hot 21 gauge needle
Silastic sleeve:
- .058" ID .077" OD silicone tubing, approx. 1 inch in length
- (not sure of current source)
Sliastic adhesive:
- A-100: Medical Silicone Adhesive 2 oz/57g tube (formerly Corning Silastic Medical Adhesive Silicone Type A)
- Purchased from Factor II, inc #A-100 $31.95
- (required considerable paperwork, including affidavit that we wouldn't use in humans.)