| | ==Supplies== | | ==Supplies== |
| | | | |
| − | New Truliner Denture Lining Standard Kit, Pink [http://www.bosworth.com/product_detail.asp?PRD_ID=18 Bosworth #0921970] $45.00 | + | ===Plastics One Cannulas and Screws=== |
| | + | |
| | + | :[http://www.plastics1.com Plastics One] |
| | + | :6591 Merriman Rd |
| | + | :Roanoke VA 24018 |
| | + | :Tel: 540-772-7950 |
| | + | :Fax: 540-777-5900 |
| | + | |
| | + | ''Check prices on annual price list.'' |
| | + | |
| | + | ====22 Gauge guide cannulas for ventricular injections:==== |
| | + | |
| | + | Use C313 components, which provide 28 gauge dummy and injectors. |
| | + | e.g., for guide cannula(G) projecting 5 mm below skull surface, |
| | + | with large-cap dummy cannulas (DC) and injectors (I) projecting 1 mm beyond tip of the guide cannula: |
| | + | |
| | + | :C313G/SPC 5 mm |
| | + | :C313DC/SPC(LG) for 5 mm C313G with 1 mm projection |
| | + | :C313I/SPC for 5 mm C313G with 1 mm projection |
| | + | |
| | + | ====26 Gauge guide cannulas for site-specific injections==== |
| | + | |
| | + | Use C315 components, which provide 33 gauge dummy and injectors. |
| | + | e.g., for guide cannula(G) projecting 8 mm below skull surface, |
| | + | with small-cap dummy cannulas (DC) and injectors (I) projecting 0.5 mm beyond tip of the guide cannula: |
| | + | |
| | + | :C315G/SPC 8 mm |
| | + | :C315DC/SPC(SM) for 8 mm C315G with 0.5 mm projection |
| | + | :C315I/SPC for 8 mm C315G with 0.5 mm projection |
| | + | |
| | + | ====Screws for skull==== |
| | + | |
| | + | We use screws of 0-80 size with shaft length 3/32 inches (2.4 mm). |
| | + | These are a little long, but they are stronger and easier to work with than 1/16 inch (1.6 mm) long screws. |
| | + | Also need the small drill pit. |
| | + | |
| | + | :0-80 X 3/32 (packages of 100) |
| | + | :D#56 1.18 mm Drill Bit for 0-80 screws |
| | + | |
| | + | |
| | + | ---- |
| | + | |
| | + | ===Other supplies needed - more detail to come=== |
| | + | |
| | + | ====Pin Vise for hand drilling the screws==== |
| | + | |
| | + | Most pin vises are nickel plated, and so cannot be autoclaved but must be sterilized e.g. with 70% EtOH. |
| | + | :VWR 63041-530 Pin Vise - Double-Ended, stainless steel |
| | + | |
| | + | Little tubing for washer around top of guide cannula? |
| | + | |
| | + | |
| | + | Superglue |
| | + | |
| | + | Size of screwdriver? source of SS screw drivers? |
| | + | |
| | + | Trephin drill bits |
| | + | |
| | + | Hamilton microsyringe and needle |
| | + | |
| | + | PE-50 tubing to connect with injector |
| | + | |
| | + | Syringe Pump |
| | + | |
| | + | |
| | + | ====New Truliner Denture Lining Standard Kit, Pink==== |
| | + | |
| | + | From either Henry Schein Dental, #2502527EZ, $105.29, or, |
| | + | [http://www.bosworth.com/product_detail.asp?PRD_ID=18 Bosworth #0921970] $45.00 |
| | | | |
| | :Harry J. Bosworth Company | | :Harry J. Bosworth Company |