| Line 3: |
Line 3: |
| | For other stereotaxic coordinates, see also [[Amygdala]], [[JA Lateral Hypothalamus Lesions]]. | | For other stereotaxic coordinates, see also [[Amygdala]], [[JA Lateral Hypothalamus Lesions]]. |
| | | | |
| − | ==Lateral Ventricular Cannula:== | + | ==Lateral Ventricular Cannula== |
| | | | |
| | 1.2 mm caudal to bregma | | 1.2 mm caudal to bregma |
| Line 11: |
Line 11: |
| | 4 mm below the skull surface | | 4 mm below the skull surface |
| | | | |
| − | ===Method===
| |
| | | | |
| | Under isoflurane anesthesia, each rat was stereotaxically implanted with a 22-gauge, stainless steel, guide | | Under isoflurane anesthesia, each rat was stereotaxically implanted with a 22-gauge, stainless steel, guide |
| Line 19: |
Line 18: |
| | except during injections when it was removed and replaced with an 28-gauge injector that extended 1.0 mm beyond the tip of the guide cannula. | | except during injections when it was removed and replaced with an 28-gauge injector that extended 1.0 mm beyond the tip of the guide cannula. |
| | | | |
| − | ===Test===
| |
| | To test the patency and placement of the cannula in the lateral ventricle, water-replete rats were injected with | | To test the patency and placement of the cannula in the lateral ventricle, water-replete rats were injected with |
| | 100 ng human angiotensin II (Ang II; Sigma Chemical Co, St Louis, MO) dissolved in 5 µl volume of saline (0.15 M). | | 100 ng human angiotensin II (Ang II; Sigma Chemical Co, St Louis, MO) dissolved in 5 µl volume of saline (0.15 M). |
| Line 28: |
Line 26: |
| | ICV injections of 5 µl volume were given by hand to lightly restrained rats using a 50 µl Hamilton microsyringe. | | ICV injections of 5 µl volume were given by hand to lightly restrained rats using a 50 µl Hamilton microsyringe. |
| | | | |
| − | ==Fourth Ventricular Cannula:== | + | ==Fourth Ventricular Cannula== |
| | | | |
| | 3.2 mm caudal to lambda | | 3.2 mm caudal to lambda |
| Line 36: |
Line 34: |
| | 7.2 mm below the skull surface | | 7.2 mm below the skull surface |
| | | | |
| − | ===Method===
| |
| | Under isoflurane anesthesia, each rat was stereotaxically implanted with a single 22-gauge stainless steel guide cannula | | Under isoflurane anesthesia, each rat was stereotaxically implanted with a single 22-gauge stainless steel guide cannula |
| | (model C315G; Plastics One, Inc., Roanoke, VA) aimed towards the fourth ventricle (4V). The tip of the guide cannula | | (model C315G; Plastics One, Inc., Roanoke, VA) aimed towards the fourth ventricle (4V). The tip of the guide cannula |
| Line 45: |
Line 42: |
| | replaced with a 28-gauge injector that extended 1.0 mm beyond the tip of the guide cannula. | | replaced with a 28-gauge injector that extended 1.0 mm beyond the tip of the guide cannula. |
| | | | |
| − | ===Test===
| |
| | To test the patency and placement of the cannula in the lateral ventricle, water-replete rats were injected with | | To test the patency and placement of the cannula in the lateral ventricle, water-replete rats were injected with |
| | XXX ng bombesin (California Peptides) dissolved in 5 µl volume of saline (0.15 M). The volume of all icv injections | | XXX ng bombesin (California Peptides) dissolved in 5 µl volume of saline (0.15 M). The volume of all icv injections |
| Line 66: |
Line 62: |
| | ''Check prices on annual price list.'' | | ''Check prices on annual price list.'' |
| | | | |
| − | ====22 Gauge guide cannulas for ventricular injections:==== | + | ====22 gauge guide cannulas for ventricular injections==== |
| | | | |
| | Use C313 components, which provide 28 gauge dummy and injectors. | | Use C313 components, which provide 28 gauge dummy and injectors. |
| Line 76: |
Line 72: |
| | :C313I/SPC for 5 mm C313G with 1 mm projection | | :C313I/SPC for 5 mm C313G with 1 mm projection |
| | | | |
| − | ====26 Gauge guide cannulas for site-specific injections==== | + | ====26 gauge guide cannulas for site-specific injections==== |
| | | | |
| | Use C315 components, which provide 33 gauge dummy and injectors. | | Use C315 components, which provide 33 gauge dummy and injectors. |
| Line 90: |
Line 86: |
| | We use screws of 0-80 size with shaft length 3/32 inches (2.4 mm). | | We use screws of 0-80 size with shaft length 3/32 inches (2.4 mm). |
| | These are a little long, but they are stronger and easier to work with than 1/16 inch (1.6 mm) long screws. | | These are a little long, but they are stronger and easier to work with than 1/16 inch (1.6 mm) long screws. |
| − | Also need the small drill pit. | + | Also need the small drill bit. |
| | | | |